G40.21 Mechanical Requirements for Plates, Bars, and Shapes
Grade |
Tensile, ksi |
Yield, ksi min, up to 2-1/2” |
Yield, ksi min, above 2-1/2” to 4” |
Elongation, % min, Longitudinal in 8” |
38W |
60-85 |
38 |
36 |
20 |
44W |
65-90 |
44 |
40 |
20 |
50W |
65-95 |
50 |
46 |
19 |
55W |
70-95 |
55 |
- |
18 |
60W |
75-100 |
60 |
- |
16 |
70W |
85-115 |
70 |
- |
15 |
80W |
90-125 |
80 |
- |
13 |
38WT |
60-85 |
38 |
36 |
20 |
44WT |
65-90 |
44 |
40 |
20 |
50WT |
70-95 |
50 |
46 |
19 |
60WT |
75-100 |
60 |
- |
18 |
70WT |
85-115 |
70 |
- |
15 |
80WT |
90-125 |
80 |
- |
13 |
50R |
70-95 |
50 |
- |
19 |
50A |
70-95 |
50 |
50 |
19 |
60A |
75-100 |
60 |
- |
18 |
70A |
85-115 |
70 |
- |
15 |
80A |
90-125 |
80 |
- |
13 |
50AT |
70-95 |
50 |
50 |
19 |
60AT |
75-100 |
60 |
- |
18 |
70AT |
85-115 |
70 |
- |
15 |
80AT |
90-125 |
80 |
- |
13 |
100Q |
110-130 |
100 |
90 |
18 in 2” |
100QT |
110-130 |
100 |
90 |
18 in 2” |
The above table has been abridged for clarity and relevance. The complete table can be found in the CSA standard at shop.csa.ca |